Securitron M68 (L, S and LS with D and T Options) Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Für Zuhause Securitron M68 (L, S and LS with D and T Options) herunter. Securitron M68 (L, S and LS with D and T Options) User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 14
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Securitron Magnalock Corp. Tel 775.355.5625
550 Vista Boulevard Fax 775.355.5633
Sparks, NV 89434 [email protected]
www.securitron.com
© Copyright, 2007, all rights reserved PN# 500-21400
Page 1 Rev. B, 8/07
ASSA ABLOY, the global leader
in door opening solutions
INSTALLATION AND OPERATING INSTRUCTIONS
For Model M38 and M68 Magnalocks
(Versions “L”, “S” and “LS” with “D” and “T” Options)
1. INTRODUCTION
Securitron’s Model M38 and M68 Magnalocks are fail safe electromagnetic locks designed for
*interior use in areas which require controlled access or egress. Each unit includes an
interlocking mounting bracket and a power and control wiring access compartment which
provides the added convenience of wiring “at-the-lock”. The sleek, low-profile design provides a
professional looking, unobtrusive integration into a wide range of architectural applications and
can be easily retrofitted to replace existing magnetic lock systems.
* M38 and M68 Magnalocks are not designed, recommended or approved for exterior (outdoor)
use. Interior use is described as any door installation to the interior of a building (i.e. offices,
work or storage rooms) or to the interior side
of any perimeter exterior door.
2. SPECIFICATIONS
M38:
M68:
Holding Force: 600 Lbs. [272 Kg] Holding Force: 1,200 Lbs. [544 Kg]
Dimensions:
Inches: 10-1/2”L X 2-9/16”H X 1-9/16”D
Millimeters: 267 L X 65 H X 40 D
Dimensions:
Inches: 10-1/2”L X 3-5/8”H X 1-13/16”D
Millimeters: 267 L X 92 H X 46 D
Electrical:
12 Volts DC:
Current Requirement: 300 – 325 mA
Power Consumption: 3.6 Watts
24 Volts DC:
Current Requirement: 150 – 175 mA
Power Consumption: 3.6 Watts
Electrical:
12 Volts DC:
Current Requirement: 250 – 275 mA
Power Consumption: 3.0 Watts
24 Volts DC:
Current Requirement: 125 -150 mA
Power Consumption: 3.0 Watts
3. PRODUCT OVERVIEW
Upon unpacking this product, an inventory should be made to ensure that all the required
components and hardware have been included. Along with these instructions and the
installation template, the lock assembly (M38 Shown) should include the following items:
Mounting Bracket
Sex Bolt
Hardware Pack
Strike Plate
Magnetic Lock
Housing
Seitenansicht 0
1 2 3 4 5 6 ... 13 14

Inhaltsverzeichnis

Seite 1

Securitron Magnalock Corp. Tel 775.355.5625 550 Vista Boulevard Fax 775.355.5633 Sparks, NV 89434 [email protected] www.securitron.com

Seite 2 - Page 2 Rev. B, 8/07

PN# 500-21400 Page 10 Rev. B, 8/07 NCCNOINREFSERIES M38 OR M68 WITH "T" OPTION(TAMPER INDICATION SWITCH)ACCESS CONTROL SYSTEMLOCK TA

Seite 3 - Page 3 Rev. B, 8/07

PN# 500-21400 Page 11 Rev. B, 8/07 8. APPENDICES A. WIRE GAUGE SIZING If the power supply is distant from the lock, voltage will be lost (dro

Seite 4 - Page 4 Rev. B, 8/07

PN# 500-21400 Page 12 Rev. B, 8/07 can make it more difficult to secure if it is stiff or rigid. Steel doors and most particularly solid stee

Seite 5 - Page 5 Rev. B, 8/07

PN# 500-21400 Page 13 Rev. B, 8/07 right. The Senstat output is created by the strike establishing electrical contact between the leftmost an

Seite 6 - Page 6 Rev. B, 8/07

PN# 500-21400 Page 14 Rev. B, 8/07 9. WARRANTY MAGNACARE® LIMITED LIFETIME WARRANTY SECURITRON MAGNALOCK CORPORATION warrants that it will

Seite 7 - Page 7 Rev. B, 8/07

PN# 500-21400 Page 2 Rev. B, 8/07 4. RECOMMENDED TOOLS Hammer Wrench, 1/2” box-end Center punch Pliers, vise grip Drill motor Screwdrivers

Seite 8 - Page 8 Rev. B, 8/07

PN# 500-21400 Page 3 Rev. B, 8/07 5.2. Door Lock Installation Figure 1 below is a typical cross section view of an M38 installed to a metal d

Seite 9 - Page 9 Rev. B, 8/07

PN# 500-21400 Page 4 Rev. B, 8/07 ITEM QTY PART NUMBER NOMENCLATURE/DESCRIPTION 1 2 560-12050 Strike Roll Pin Bushing, Clear, Nylon 2 2 3

Seite 10 - Page 10 Rev. B, 8/07

PN# 500-21400 Page 5 Rev. B, 8/07 5.2.2. Door Frame Preparation Figure 3 below is an exploded illustration of the assembly of the lock to a m

Seite 11 - Page 11 Rev. B, 8/07

PN# 500-21400 Page 6 Rev. B, 8/07 ITEM QTY PART NUMBER NOMENCLATURE/DESCRIPTION 8 1 (Included) Phillips Flat Head Screw, 8-32 UNC 9 1 (In

Seite 12 - Page 12 Rev. B, 8/07

PN# 500-21400 Page 7 Rev. B, 8/07 a. For Metal Door Frame: Two (2) 1/4”-20 UNC X 1” long Phillips pan head screws (Item #13) provided. b. Fo

Seite 13 - Page 13 Rev. B, 8/07

PN# 500-21400 Page 8 Rev. B, 8/07 2. Using a #1 Phillips screwdriver and the screws provided secure the actuator block to the door making sur

Seite 14 - Page 14 Rev. B, 8/07

PN# 500-21400 Page 9 Rev. B, 8/07 Figure 6 Figure 7 The addition of the “D” option incorporates a door position sensing switch which indicat

Kommentare zu diesen Handbüchern

Keine Kommentare