Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader
Tel 800.624.5625 [email protected]
in door opening solutions
© Copyright, 2012, all rights reserved PN# 500-10440
Page 1 Rev. F, 02/12
SHEAR ALIGNING MAGNALOCK MODEL SAM
INSTALLATION AND OPERATING INSTRUCTIONS
1 INTRODUCTION
Securitron’s Shear Aligning Magnalock “SAM” is intended for installations where concealed
mounting in the door and frame is desired. The operating features allow self-alignment while
securing the door when it closes. The SAM is designed to operate with one-way swing, bi-
directional swing or sliding type doors. The lock is also capable of securing bi-parting motorized
sliding doors. On swing type doors the lock installs horizontally in the top or bottom of the door
frame or may be installed vertically in the door frame side. For slider type door applications the
locks must be installed horizontally for proper operation. These units have also been designed to
unlock even if a preload is applied to the door.
The SAM BondSTAT “B” Series, Bond Sensor, monitors the magnetic field. An internal sensor
activates a SPDT dry contact relay connection designed for interface to access control and/or
alarm systems for reporting the status of the Magnalock. (See Section 5.6.6)
The DPS “D” Series, Door Position Sensor, is activated by a special magnetic strike armature
assembly. The isolated SPDT reed switch, with an internal resettable protection device, is
designed for interface to access control and/or alarm system for door status. (See Section
5.6.6)
2 SPECIFICATIONS
MODEL SAM
Holding Force
1200 Lbs [544kg]
Dimensions: Length
10.85" [275mm]
Height
1.5" [38mm]
Depth
1.19" [30mm]
Dual Voltage
12/24 Volts DC
Current: @ 12 VDC
320mA
@ 24 VDC
170mA
Capacitance: @ 12 VDC
6.8mF
@ 24 VDC
6.8mF
BondSTAT Rating
Voltage: 30 VDC (Maximum)
Current: 1 Amp (Maximum)
DPS Rating
Voltage: 30 VDC (Maximum)
Current: 125 mA (Maximum)
3 PRODUCT OVERVIEW
Upon unpacking this product, an inventory should be made to ensure that all the required
components and hardware have been included. Along with these instructions and the
installation template, each product should include the following items:
Figure 1 - SAM Series Magnalock
Magnalock
Strike Assembly
Hardware Pack
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1

Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solution

Seite 2 - Page 2 Rev. F, 02/12

PN# 500-10440 Page 10 Rev. F, 02/12 attracted to the Magnalock, but the strike and the interference buttons should pass completely into the lo

Seite 3 - Page 3 Rev. F, 02/12

PN# 500-10440 Page 11 Rev. F, 02/12 6.5 Electrical Wiring The following diagrams, Figures 17, 18, 19 and 20 represent the proper electrical

Seite 4 - Page 4 Rev. F, 02/12

PN# 500-10440 Page 12 Rev. F, 02/12 6.6 BondSTAT Sensor status wiring description  The green and white wires supply electrical connection w

Seite 5 - (Note Orientation)

PN# 500-10440 Page 13 Rev. F, 02/12 8 MAGNALOCK MAINTENANCE 8.1 Visual Inspection  Check the strike assembly for proper gap, suspension an

Seite 6 - Door Recess

PN# 500-10440 Page 14 Rev. F, 02/12 Problem DPS Does Not Report Door Status Points of Reference Check strike mounting for proper alignment

Seite 7 - 2" [50.8]

PN# 500-10440 Page 15 Rev. F, 02/12 1.2.2 Example B: (24VDC system) Using Table 2 (24VDC) Find: - Current Draw .600 Amps - Wire Distan

Seite 8 - Page 8 Rev. F, 02/12

PN# 500-10440 Page 16 Rev. F, 02/12 MAGNACARE LIFETIME REPLACEMENT WARRANTY For warranty information visit www.securitron.com/en/site/securit

Seite 9

PN# 500-10440 Page 2 Rev. F, 02/12 3.1 HARDWARE 10X 20X 1X Phillips Flat Head #10 X 3/4” Type “A” Socket Flat Head 10-32 X 3/8” Hex

Seite 10 - Page 10 Rev. F, 02/12

PN# 500-10440 Page 3 Rev. F, 02/12 The door and frame areas additionally need to be examined for mortising capabilities, sufficient size and s

Seite 11 - Page 11 Rev. F, 02/12

PN# 500-10440 Page 4 Rev. F, 02/12 Locate and mark the desired lateral centerline position for the Magnalock/strike assembly on the face of th

Seite 12 - Page 12 Rev. F, 02/12

PN# 500-10440 Page 5 Rev. F, 02/12 It is recommended that the Magnalock face protrude approximately 1/16” [1.6mm] beyond the surface of the fr

Seite 13 - Page 13 Rev. F, 02/12

PN# 500-10440 Page 6 Rev. F, 02/12 The serrations on the brackets are .050” [1.3mm] apart which matches the screw thread pitch distance that m

Seite 14 - (800) 624-5625

PN# 500-10440 Page 7 Rev. F, 02/12 5.6.3 Hollow Aluminum Door (Deep Recess Top) For mounting of the strike assembly into doors with deep rece

Seite 15 - IMPORTANT

PN# 500-10440 Page 8 Rev. F, 02/12 5.6.5 Soft Core Wood Door Use of the end brackets is recommended when installing the strike assembly on so

Seite 16 - Page 16 Rev. F, 02/12

PN# 500-10440 Page 9 Rev. F, 02/12 Slider Door Installation Figure 13 5.7 Strike Assembly Final Adjustments 5.7.1 Strike Level Adjustment

Kommentare zu diesen Handbüchern

Keine Kommentare