INTEGRATED EXIT DELAY SYSTEM MODEL iMXDa AND iEXDa
INSTALLATION AND OPERATING INSTRUCTIONS
1. INTRODUCTION
The Securitron iMXDa represents the state of the art in electromagnetic locking with integrated
exit delay. This system incorporates Securitron’s BondSTAT and DPS (Door Position Sensor)
Magnalock technology along with intelligent microprocessor based, alarm options and a trainable
door movement feature. The unit is auto sensing dual voltage (12/24 VDC) and provides a
variety of easily selectable operating functions. The iEXDa is a similar product featuring external
initiate using a UL listed egress device.
Securitron also offers a City of Chicago and State of California compliant versions.
2. SPECIFICATIONS
MODEL iMXDa/iEXDa
Holding Force 1200 Lbs [544 kg]
Dimensions: Length
12.5" [318mm]
Height
3.63" [92mm]
Depth
2" [51mm]
Dual Voltage
12/24 Volts DC
Current: @ 12 VDC
370mA
@ 24 VDC
270mA
Capacitance: @ 12 VDC
32 mF
@ 24 VDC
32 mF
Door Movement (Gap)
Sensing Range
1/8” [3.2mm] to
1” [25.4mm]
External Alarm Rating
Voltage: 30 VDC (Maximum)
Current: 1 Amp (Maximum)
DPS (DS) Rating
Voltage: 30 VDC (Maximum)
Current: 125 mA (Maximum)
Tamper (TS) Rating
Voltage: 30 VDC (Maximum)
Current: 2 Amps (Maximum)
3. PRODUCT OVERVIEW
Along with the installation and operating
instruction manual, the quick start guide, and
the mounting templates, the product package
should include:
Figure 1
4. RECOMMENDED TOOLS
Hammer
Center Punch
Power Drill
Drill bits: 9/64”, 3/16”, 7/32”, 3/8”, and
1/2” (iEXDa) or 1” (iMXDa) Diameters
Wrenches: 7/16” open end (or adjustable),
1/2” box/open end (or adjustable), 1-1/4”
open end (or 12” adjustable), 3/16” Hex
Key (Allen) and 3/32” Hex Key (Allen)
Pliers, vise grip
Screwdrivers: #1, #2 and #3 Phillips
1/8” Flat Blade
Masking Tape
Fish Tape or Lead Wire
Wire Strippers/Cutter
Multimeter
SB-MXD
Sex Bolt
(iMXDa)
Hardware Pack
Actuator
Standard
Sex Bolt
(iEXDa)
Mounting
Bracket
(DPS) Strike Plate
Lock Housing
Seitenansicht 0
1 2 3 4 5 6 ... 18 19

Inhaltsverzeichnis

Seite 1 -  Multimeter

Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions

Seite 2 - Page 2 Rev. A, 11/12

P/N 500-22155 Page 10 Rev. A, 11/12 To meet regulatory and code requirements, some settings are disabled or not adjustable on the California

Seite 3 - Page 3 Rev. A, 11/12

P/N 500-22155 Page 11 Rev. A, 11/12 Operation 8 Position DIP Directive SW1 SW2 Seconds Factory Default Setting California setting Chica

Seite 4 - Page 4 Rev. A, 11/12

P/N 500-22155 Page 12 Rev. A, 11/12 BEA (Bypass Expiration Alarm) – DIP SW7 The bypass expiration alarm is an audible rapid 4-beep signal that

Seite 5 - Page 5 Rev. A, 11/12

P/N 500-22155 Page 13 Rev. A, 11/12 External Controls The unit is also has terminals which provide the connections necessary for remote control

Seite 6 - Page 6 Rev. A, 11/12

P/N 500-22155 Page 14 Rev. A, 11/12 Tamper Status (JP1) and Door Status (JP2) wiring The Tamper Status function can only be operated in units w

Seite 7 - Page 7 Rev. A, 11/12

P/N 500-22155 Page 15 Rev. A, 11/12 8. MAGNALOCK MAINTENANCE Visual Inspection  Check the rubber washers for elasticity and proper pivoting.

Seite 8 - Page 8 Rev. A, 11/12

P/N 500-22155 Page 16 Rev. A, 11/12 APPENDIX A Troubleshooting Problem No Alarm when Testing Door Movement Points of Reference Check for spe

Seite 9 - Page 9 Rev. A, 11/12

P/N 500-22155 Page 17 Rev. A, 11/12 APPENDIX B Wire Gauge Factoring Remote Power Supply  The iMXDa/iEXDa requires adequate voltage and curren

Seite 10 - Page 10 Rev. A, 11/12

P/N 500-22155 Page 18 Rev. A, 11/12 APPENDIX C Mortise Cylinder/Cam The mortise cylinder and cam is field replaceable. The cylinder is retaine

Seite 11

P/N 500-22155 Page 19 Rev. A, 11/12 iMXDa-CH – City of Chicago Operational Information This addresses the operating notifications specifically

Seite 12 - Page 12 Rev. A, 11/12

P/N 500-22155 Page 2 Rev. A, 11/12 5. INSTALLATION INSTRUCTIONS Pre-Installation Survey A site survey should be performed to determine the mou

Seite 13 - Page 13 Rev. A, 11/12

P/N 500-22155 Page 3 Rev. A, 11/12  Read and follow the instructions on Product Template which includes drilling and mounting directions. 

Seite 14 - Page 14 Rev. A, 11/12

P/N 500-22155 Page 4 Rev. A, 11/12 DO NOT OVERTIGHTEN THE STRIKE/SEX BOLT ASSEMBLY AS THIS CAN CAUSE DAMAGE TO THE RUBBER WASHERS AND MAY PREV

Seite 15 - Page 15 Rev. A, 11/12

P/N 500-22155 Page 5 Rev. A, 11/12 9. FOR METAL DOOR FRAME: Drill four (4) 3/16” [4.8mm] diameter holes through the frame. a. Using a #3 Phi

Seite 16 - APPENDIX A

P/N 500-22155 Page 6 Rev. A, 11/12 All wiring to the installed unit is made to the main terminal strip on the PC board inside the wire access c

Seite 17 - Page 17 Rev. A, 11/12

P/N 500-22155 Page 7 Rev. A, 11/12 Figure 8 Connections for a 2 to 4.5 Amp (BPS) Power Supply Figure 9 Connections for a 6 to 15 Amp (BPS) P

Seite 18 - IMPORTANT

P/N 500-22155 Page 8 Rev. A, 11/12 6. SYSTEM OPERATIONS General Description of Operation The iMXDa secures an opening using a model 62 Magnalo

Seite 19

P/N 500-22155 Page 9 Rev. A, 11/12 Standard Operational Mode This is the mode in which the iMXDa unit operates most of the time. When the door